Equipment tiers · 6 of 9 · 1 min read

Power and amps

Check power first, before brand. Here are real examples from product pages, so you can see how much they vary. They are examples only, not recommendations, and specs can change.

ItemPower listed on the product pageWhat that meansProduct page
Riley Hopkins Flash 16×16 (flash)1600W, 120V, 13.4A, NEMA 5-15PStandard plug, but a big share of a 15A circuitScreenPrinting.com (maker)
RileyFlash 18×18 (flash)2300W, 120V, 19.2A, NEMA 5-20P; “requires a dedicated 20 amp circuit”Needs its own 20A circuitScreenPrinting.com (maker)
Vastex F-100 16×16 (flash)1,625W; 120V (NEMA 5-15P) or 240V (NEMA 6-15P)Standard plug at 120VTexsource (dealer)
Genesis coil flash 16×16 / 18×181,800W / 2,000W; 15A, 120VOrdinary 120V outlet; don’t share the circuit with the dryerTexsource (seller)
BBC MB1500 (tabletop conveyor)120V, 12.5A, 1440W, NEMA 5-15PStandard plugTexsource (dealer)
Vastex D-100 (tabletop conveyor)120V 12.5A (NEMA 5-15P) or 240V 6.5A (NEMA 6-15P)Standard plug at 120VTexsource (dealer)
RileyCure Table Top Plus (conveyor)1600W, 120V, 13.8A, NEMA 5-15PStandard plug, but a big share of a 15A circuitScreenPrinting.com (maker)
Lawson Kick-Start IR (conveyor)“standard 120-volt plug-in household wiring”; spec table: 120V, 16AA 120V plug, but 16A is a heavy load for a household circuit: have an electrician check itLawson (maker)
BBC Little Buddy 120V (conveyor)1941W, 120VAC 16.2A, NEMA 5-20PNeeds a 20A outlet (5-20 plug)ScreenPrinting.com (dealer)
Vastex LittleRed X1 30" (conveyor)120V/2000W/16.5A (NEMA 5-20P) or 240V/2600W/11A (NEMA 6-15P)20A outlet at 120V, or a 240V outletTexsource (dealer)
Lawson Kick-Start Advanced (forced-air)220V, 3 wires + ground, est. 18A; 4,000W max heaterA 220–240V circuit: electrician territoryLawson (maker)
RileyCure 246 (6 ft × 24")208/240VAC, 14.4/16.7A, NEMA 6-20P; “requires a dedicated 208v or 240v 30 amp circuit”Electrician territoryScreenPrinting.com (maker)

Each row was re-checked against the linked product page on October 8, 2026 (the maker’s own page where noted, otherwise a dealer’s page). Examples only, not recommendations. Specs change: check the current manual before you buy.

Running a flash and a dryer at the same time adds their amps together. The “dedicated circuit” lines are quoted from the product pages; for anything else, read the manual and the plug type, and have an electrician check your panel and circuit. That last part is our advice, not a sourced spec.

Sources for this guide (17)
  1. ScreenPrinting.com Help, What do I need to start a shop?
  2. ScreenPrinting.com Help, How do I pick the right press?
  3. ScreenPrinting.com, Which screen printing press is right for me?
  4. Lawson Screen & Digital, Curing plastisol inks
  5. International Coatings, Curing ink with a heat gun
  6. ScreenPrinting.com, 4 curing methods
  7. ScreenPrinting.com Help, How do you cure plastisol with a flash dryer?
  8. Avient, Mapping your conveyor dryer (PDF)
  9. Ink Kitchen, Buying used screen printing equipment (July 2026)
  10. Ink Kitchen, Why out of register? Let me count the ways
  11. Signs101 forum, Where to find used equipment
  12. Signs101 forum, Looking for a new or used conveyor dryer
  13. Screen Printing Magazine, Stencilmaking in the age of CTS
  14. ScreenPrinting.com, Compression vs. vacuum exposure units
  15. OSHA, Hazard Communication (29 CFR 1910.1200)
  16. NIOSH, Health hazard evaluation 2007-0053-3092 (PDF)
  17. Cedar City, UT, Screen printers best management practices

Where sources disagree, the page says so.